Характеристики серии

Max. Raw Capacity:

1440TB

Internal Drives:

12

Performance HDD:

N/A

Capacity HDD:

4TB, 8TB, 10TB

SSD:

960GB, 3.84TB

Self-encrypting Drives:

800GB SSD, 3.8TB SSD, 6TB at 7.2K RPM AES-256, FIPS 140-2 compliant

Maximum Drives (Internal + External):

144 (same for both models)

ECC Memory:

64GB

Controller Form Factor:

1 or 2 controllers in a single 2U chassis (same for both models)

Onboard NetApp NVMe Flash Cache:

1TB (same for both models)

Maximum Flash Pool:

24 TB (same for both models)

NVMEM/NVRAM:

8GB (same for both models)

Onboard 10GbE:

4 (same for both models)

Onboard I/O: UTA2 (8Gb FC/16Gb FC/FCoE/10GbE/1GbE:

8 (same for both models, Unified configuration only)

Onboard I/O: 10GBASE-T (10GbE, 1GbE):

8 (same for both models, Ethernet configuration only)

Onboard I/O: 12Gb SAS:

4 (same for both models)

NAS Scaling:

1–24 nodes (12 HA pairs)

SAN Scaling:

1–12 nodes (6 HA pairs)

Maximum Drives:

1728

Maximum Raw Capacity:

17.1PB

Maximum onboard NetApp NVMe Flash Cache:

12TB

Maximum Flash Pool:

288TB

Maximum Memory:

768GB

Cluster Interconnect:

10GbE, supported using either 10GbE or UTA2 ports for maximum flexibility

Storage Protocols Supported:

FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB

OS Version:

ONTAP 9.4 or later

High-Availability Features:

SAS in-band management over SAS connections; 
Ethernet-based Service Processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, and power supplies

Supported Configurations:

Hardware Cluster Configurations

  • Single-node cluster
  • Two-node switchless cluster
  • Two-node switched cluster
  • Clusters of HA pairs

Back-End Disks: Single path with single controller or HA pair; dual path with single controller MP-HA with HA pair (best practice)
Consult the Interoperability Matrix Tool for FAS2600 support on earlier versions of ONTAP software.

Disk Shelves Supported:

DS212C (2U; 12 drives, 3.5” LFF)
DS224C (2U; 24 drives, 2.5″ SFF)
DS460C (4U; 60 drives, 3.5” LFF)
DS2246 (2U; 24 drives, 2.5″ SFF)
DS4246 (4U; 24 drives, 3.5″ LFF, 6Gb)

Maximum RAID Group Sizes:

RAID-TEC™ (triple parity, ONTAP 9)

  • SSDs and Performance HDDs: 29 (26 data disks plus 3 parity disks)
  • Capacity HDDs: 29 (26 data disks plus 3 parity disks)

RAID 6 (RAID-DP®)

  • SSDs and Performance HDDs: 28 (26 data disks plus 2 parity disks)
  • Capacity HDDs: 20 (18 data disks plus 2 parity disks)

RAID 4

  • SSDs and Performance HDDs: 14 (13 data disks plus 1 parity disk)
  • Capacity HDDs: 7 (6 data disks plus 1 parity disk)

RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®)

Host/Client Operating Systems Supported:

Windows 2000, Windows Server 2003, Windows Server 2008, Windows Server 2012, Windows Server 2016, Linux®, Oracle® Solaris, AIX, HP-UX, Mac OS, VMware, ESX

Max. Number of LUNs:

2048 per controller

Number of Supported Hosts:

Up to 4 ports per controller configured as front-end (host) connectivity ports
Up to 8 directly connected servers per active-active configuration
Connected hosts per HA pair: Up to 512 SAN connected servers

FlexVol Volumes:

Up to 1,000 per controller

Snapshot Copies:

Up to 255,000 per controller

Maximum Volume Size:

100TB

Maximum Aggregate Size:

400TB

Thermal Rating (at 110V):

1,219 BTU (typical)
1,697 BTU (worst case)

Power supply / cooling fans:

Dual, hot pluggable, integrated power supply/fan assemblies

AC input power voltage (autoranging, VRMS):

100-120V, 200-240V

AC input power frequency:

50-60 Hz

Chassis Height:

3.35” (8.5 cm)

Width (without mounting flanges) :

17.6” (44.7 cm)

Depth (without cable management brackets):

19″ (48 cm)

Weight:

60.85 lbs (27.6 kg)

Operating temperature, altitude, and relative humidity:

41°F to 113°F (5°C to 45°C); at ≤ 3,000m (at ≤ 10,000′) elevation; 8% to 90% relative humidity, noncondensing

Nonoperating temperature and relative humidity:

-40°F to 158°F (-40°C to 70°C); at ≤ 12,192m (at ≤ 40,000′) typical of unconditioned airplane cargo bay, 10% to 95% relative humidity, noncondensing, in original container

Operating acoustic noise:

Declared sound power (LwAd) per ISO 9296: 6.9 Bels
Sound pressure (LpAm) (bystander positions): 51

Safety/ Emissions/ Immunity:

Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, CU, BIS, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI

Официальный сайт:

http://www.netapp.com

Подберем и рассчитаем конфигурацию...

E5612_1

© 2012-2019 Технологическое партнерство.

Click Me