Характеристики серии

NAS Scale-out:

2-24 nodes (12 HA pairs)

Maximum SSD:

1,728

Maximum Raw Capacity:

48.3PB/42.9PiB

Effective Capacity:

193.3PB/171.6PiB

Maximum Memory:

768GB

SAN Scale-out:

2-12 nodes (6 HA pairs)

Maximum SSD:

864

Maximum Raw Capacity:

24.2PB/21.4PiB

Effective Capacity:

96.7PB/85.5PiB

Maximum Memory:

384GB

Cluster Interconnect:

4x 10GbE

Maximum SSD:

144

Maximum Raw Capacity:

4.0PB/3.6PiB

Effective Capacity:

16.6PB/14.3PiB

Controller Chassis Form Factor:

2U chassis with two HA controllers and 24 SSD slots

Memory:

64GB

NVRAM/NVMEM:

8GB

PCIe Expansion Slots:

n/a

Onboard I/O: 100GbE / 40GbE 40GbE or 10GbE:

n/a

Onboard I/O: UTA2 (16Gb FC, 10GbE/ FCoE):

8

Onboard I/O: 10GbE:

4

Onboard I/O: config only 10Gbase-T:

n/a

Onboard I/O: 12Gb SAS:

4

Storage Networking Supported:

FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB

OS Version:

ONTAP 9.4RC1 or later

High-Availability:

SAS in-band management over SAS connections; Ethernet-based service processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, and power supplies

Supported Configurations ONTAP 9.4:

Cluster Configurations

  • Two-node switchless or switched cluster
  • Clusters of HA pairs
MetroCluster:

MetroCluster™ configurations for synchronous replication

  • 2-node
  • 4-node: two 2-node switched or switchless clusters with fabric-attached (switched) storage (4 nodes total a 2-node active-active cluster at each site)
  • 8-node (NAS-only): four 2-node switched or switchless clusters with fabric-attached (switched) storage (8 nodes total: a 4-node cluster at each site)
Supported Internal SSDs:

30.5TB (external only), 15.3TB, 7.6TB, 3.8TB, and 960GB 3.8TB and 800GB self-encrypting

Supported Storage Shelves and SSDs:

Configured with new systems:

  • Storage shelf: DS224C; 2U 24 drive, 12Gbps SAS
    • SSDs: 15.3TB, 3.8TB, and 960GB
    • Self-encrypting SSDs: 3.8TB (all system models) and 800GB (AFF A300 and AFF A200 only)

Supported when expanding system capacity or adding storage from other AFF systems:

  • Storage shelf: DS224C; 2U 24 drive, 12Gbps SAS
    • SSDs: 15.3TB, 3.8TB, and 960GB
    • Self-encrypting SSDs: 3.8TB (all system models) and 800GB
  • Storage shelf: DS2246; 2U 24 drive, 6Gbps SAS
    • SSDs: 3.8TB, 1.6TB, 800GB, and 400GB
    • Self-encrypting SSDs: 1.6TB and 800GB

Self-encrypting SSDs are AES-256, FIPS 140-2 compliant

Maximum RAID Group Sizes:

RAID-TEC™ (triple parity RAID, supported with ONTAP 9.0 and later)
SSD: 29 (26 data drives plus 3 parity drives)
RAID 6 (RAID DP)
SSD: 28 (26 data drives plus 2 parity drives)
RAID 4
SSD: 14 (13 data drives plus 1 parity drive)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®)

Host Operating Systems Supported:

Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows Server 2016, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX®

Max. Number of LUNs:

4096

Number of Supported SAN Hosts:

512

FlexVol® volumes:

Up to 1,000 per controller

Snapshot® Copies:

Up to 255,000 per controller

Maximum Volume Size:

100TiB

Maximum Aggregate Size:

400TiB in ONTAP 9.1 versions
800TiB in ONTAP 9.2 and later

Maximum port counts:

100GbE / 40GbE ports: n/a
FC target ports (32Gb autoranging): n/a
FC target ports (16Gb autoranging): 8
FC target ports (8Gb or 4Gb): 8
FCoE target ports, UTA2: 8
40GbE ports: n/a
10GbE ports: 8
10Gbase-T ports (1GbE autoranging): n/a
12Gb/6Gb SAS ports: 4
FC initiator ports: 8

Thermal Rating (at 200VAC):

1,209 BTU/hr (typical)
1,676 BTU/hr (worst case)
Dual-controller chassis with 24x 3.8TB SSD

Weight:

60.8 lb (27.6 kg)
Dual-controller chassis with 24x 3.8TB SSD

Height:

2U

Width:

19″ IEC rack-compliant (17.6″, 44.7 cm)

Depth:

19” (without cable management bracket)

Operating Temperature, Altitude, and Relative Humidity:

5°C to 45°C (41°F to 113°F) at ≤3,048 m (≤10,000 ft) elevation; 8% to 90% relative humidity, noncondensing

Nonoperating Temperature and Relative Humidity:

-40°C to 70°C (-40°F to 158°F) up to 12,192 m (40,000 ft)
10% to 95% relative humidity, noncondensing, in original container

Operating Acoustic Noise (at 23°C and at sea level):
  • Declared sound power (LwAd) per ISO 9296: 6.9 Bel
  • Sound pressure (LpAm) (bystander positions): 51 dB

Measured configured with 24x 3.8TB SSD

Safety/Emissions/Immunity:

Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI

Rack Space:

42U

Dimensions (height/width/depth):

78.75″ (200 cm)/23.6″ (60 cm)/44.3″ (112.5 cm)

Minimum Cabinet Clearances for Airflow:

10″ (25.4 cm) front and 12″ (30.5 cm) rear

Minimum Cabinet Clearances for Service:

30″ (76.3 cm) front and rear, 12″ top

AC Power:

200 to 240VAC

Current:

30A Single Phase or 3-Phase

Weight (empty):

307 lbs (138 kg)

Features:

Split rear door with cable egress opening, reversible front door (left or right handed)