2-24 nodes (12 HA pairs)
2-24 nodes (12 HA pairs)
5760
175.7PB/156.0PiB
702.7PB/623.8PiB
12,288GB
2-12 nodes (6 HA pairs)
2880
87.8PB/78.0PiB
351.4PB/311.9PiB
6144GB
4x 40GbE
480
14.6PB/13.0PiB
58.6PB/52.0PiB
8U chassis with two HA controllers
1024GB
64GB
20
n/a
8
n/a
n/a
n/a
NVMe/FC; FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB
ONTAP 9.1 RC1 or later
SAS in-band management over SAS connections; Ethernet-based service processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, and power supplies
Cluster Configurations
MetroCluster™ over TCP/IP configurations for synchronous replication in ONTAP 9.3 and later
MetroCluster™ configurations for synchronous replication
30.5TB, 15.3TB, 7.6TB, 3.8TB, and 960GB 3.8TB and 800GB self-encrypting
Configured with new systems:
Supported when expanding system capacity or adding storage from other AFF systems:
Self-encrypting SSDs are AES-256, FIPS 140-2 compliant
RAID-TEC™ (triple parity RAID, supported with ONTAP 9.0 and later)
SSD: 29 (26 data drives plus 3 parity drives)
RAID 6 (RAID DP)
SSD: 28 (26 data drives plus 2 parity drives)
RAID 4
SSD: 14 (13 data drives plus 1 parity drive)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®)
Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows Server 2016, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX®
12,288
8,192
Up to 1,000 per controller
Up to 255,000 per controller
100TiB
400TiB in ONTAP 9.1 versions
800TiB in ONTAP 9.2 and later
100GbE / 40GbE ports: n/a
FC target ports (32Gb autoranging): 32
FC target ports (16Gb autoranging): 64
FC target ports (8Gb or 4Gb): 64
FCoE target ports, UTA2: 64
40GbE ports: 32
10GbE ports: 64
10Gbase-T ports (1GbE autoranging): 64
12Gb/6Gb SAS ports: 64
FC initiator ports: 64
5,151 BTU/hr (typical)
5,430 BTU/hr (worst case)
Dual-controller chassis with 40GbE, 32GbE FC and 12Gb SAS I/O modules
424 BTU/hr (typical)
949 BTU/hr (worst case)
DS224C shelf with 24x 3.8TB SSD
183.0 lb (83.0 kg)
Dual-controller chassis with 40GbE, 32GbE FC and 12Gb SAS I/O modules 53.8 lb (24.4 kg) DS224C shelf with 24x 3.8TB SSD
10U (8U + 2U shelf)
19″ IEC rack-compliant (17.6″, 44.7 cm)
30.8″ (36.8″ with cable management bracket)
5°C to 45°C (41°F to 113°F) at ≤3,048 m (≤10,000 ft) elevation; 8% to 90% relative humidity, noncondensing
-40°C to 70°C (-40°F to 158°F) up to 12,192 m (40,000 ft)
10% to 95% relative humidity, noncondensing, in original container
Dual-controller chassis with 40GbE, 32GbE FC and 12Gb SAS I/O modules
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI
42U
78.75″ (200 cm)/23.6″ (60 cm)/44.3″ (112.5 cm)
10″ (25.4 cm) front and 12″ (30.5 cm) rear
30″ (76.3 cm) front and rear, 12″ top
200 to 240VAC
30A Single Phase or 3-Phase
307 lbs (138 kg)
Split rear door with cable egress opening, reversible front door (left or right handed)
© 2012-2019 Технологическое партнерство.