2-24 nodes (12 HA pairs)
2-24 nodes (12 HA pairs)
2880
79.0PB/70.2PiBB
316.3PB/280.8PiB
15,360GB
2-12 nodes (6 HA pairs)
1440
39.6PB/35.1PiB
158.2PB/140.4PiB
7680GB
4x 100GbE
240
6.6PB/5.8PiB
26.4PB/23.4PiB
4U chassis with two HA controllers and 48 SSD slots
1280GB
64GB
8
2x 100GbE or 2x 40GbE
n/a
n/a
n/a
n/a
NVMe/FC; FC; iSCSI; NFS; pNFS; CIFS/SMB
ONTAP 9.4 RC1 or later
SAS in-band management over SAS connections; Ethernet-based baseboard management controller (BMC) and ONTAP management interface; redundant hot-swappable controllers and power supplies
Cluster Configurations
MetroCluster™ over TCP/IP configurations for synchronous replication
15.3TB (coming soon), 7.6 TB, 3.8TB, and 1.9TB 3.8TB self-encrypting (coming soon)
6 drive NVMe packs for add on internal storage 6 drive NVMe packs for add on storage
Supported as part of upgrades DS224C with all supported SSDs DS2246 with all supported SSDs
RAID-TEC™ (triple parity RAID, supported with ONTAP 9.0 and later)
SSD: 29 (26 data drives plus 3 parity drives)
RAID 6 (RAID DP)
SSD: 28 (26 data drives plus 2 parity drives)
RAID 4
SSD: 14 (13 data drives plus 1 parity drive)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®)
Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows Server 2016, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX®
12,288
8,192
Up to 1,000 per controller
Up to 255,000 per controller
100TiB
400TiB in ONTAP 9.1 versions
800TiB in ONTAP 9.2 and later
100GbE / 40GbE ports: 16
FC target ports (32Gb autoranging): 32
FC target ports (16Gb autoranging): 32
FC target ports (8Gb or 4Gb): 32 (8Gb only)
FCoE target ports, UTA2: n/a
40GbE ports: 16
10GbE ports: 32
10Gbase-T ports (1GbE autoranging): n/a
12Gb/6Gb SAS ports: n/a
FC initiator ports: 32
6,369 BTU/hr (typical)
7,693 BTU/hr (worst case)
Unified 100GbE with 32Gb FC dual-controller configuration with 48x 7.6 TB NVMe SSD
134.7 lb (61.1 kg)
Unified 40GbE-32Gb FC dual-controller configura-tion with 24x 3.8TB SSD
4U
19″ IEC rack-compliant (17.6″, 44.7 cm)
34.5” (36.6” with cable management bracket)
5°C to 40°C (41°F to 104°F) at ≤3,048 m (≤10,000 ft) elevation; 8% to 90% relative humidity, noncondensing
-40°C to 70°C (-40°F to 158°F) up to 12,192 m (40,000 ft)
10% to 95% relative humidity, noncondensing, in original container
Unified 100GbE with 32Gb FC dual-controller configuration with 48x 7.6 TB NVMe SSD
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI
42U
78.75″ (200 cm)/23.6″ (60 cm)/44.3″ (112.5 cm)
10″ (25.4 cm) front and 12″ (30.5 cm) rear
30″ (76.3 cm) front and rear, 12″ top
200 to 240VAC
30A Single Phase or 3-Phase
307 lbs (138 kg)
Split rear door with cable egress opening, reversible front door (left or right handed)
© 2012-2019 Технологическое партнерство.