1243TB
1243TB
24
900GB, 1.2TB, 1.8TB
Not Applicable
960GB, 3.84TB, 7.6TB 15.3TB
800GB SSD, 3.8TB SSD, 1.8TB 10K RPM AES-256, FIPS 140-2 compliant
144 (same for both models)
64GB
1 or 2 controllers in a single 2U chassis (same for both models)
1TB (same for both models)
24 TB (same for both models)
8GB (same for both models)
4 (same for both models)
8 (same for both models, Unified configuration only)
8 (same for both models, Ethernet configuration only)
4 (same for both models)
1–24 nodes (12 HA pairs)
1–12 nodes (6 HA pairs)
1728
15.0PB
12TB
288TB
768GB
10GbE, supported using either 10GbE or UTA2 ports for maximum flexibility
FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB
ONTAP 9.4 or later
SAS in-band management over SAS connections; Ethernet-based Service Processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, and power supplies
Hardware Cluster Configurations
Back-End Disks: Single path with single controller or HA pair; dual path with single controller MP-HA with HA pair (best practice)
Consult the Interoperability Matrix Tool for FAS2600 support on earlier versions of ONTAP software.
DS212C (2U; 12 drives, 3.5” LFF)
DS224C (2U; 24 drives, 2.5″ SFF)
DS460C (4U; 60 drives, 3.5” LFF)
DS2246 (2U; 24 drives, 2.5″ SFF)
DS4246 (4U; 24 drives, 3.5″ LFF, 6Gb)
RAID-TEC™ (triple parity, ONTAP 9)
RAID 6 (RAID-DP®)
RAID 4
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®)
Windows 2000, Windows Server 2003, Windows Server 2008, Windows Server 2012, Windows Server 2016, Linux®, Oracle® Solaris, AIX, HP-UX, Mac OS, VMware, ESX
2048 per controller
Up to 4 ports per controller configured as front-end (host) connectivity ports
Up to 8 directly connected servers per active-active configuration
Connected hosts per HA pair: Up to 512 SAN connected servers
Up to 1,000 per controller
Up to 255,000 per controller
100TB
400TB
1,219 BTU (typical)
1,697 BTU (worst case)
Dual, hot pluggable, integrated power supply/fan assemblies
100-120V, 200-240V
50-60 Hz
3.35” (8.5 cm)
17.6” (44.7 cm)
19″ (48 cm)
60.85 lbs (27.6 kg)
41°F to 113°F (5°C to 45°C); at ≤ 3,000m (at ≤ 10,000′) elevation; 8% to 90% relative humidity, noncondensing
-40°F to 158°F (-40°C to 70°C); at ≤ 12,192m (at ≤ 40,000′) typical of unconditioned airplane cargo bay, 10% to 95% relative humidity, noncondensing, in original container
Declared sound power (LwAd) per ISO 9296: 6.9 Bels
Sound pressure (LpAm) (bystander positions): 51
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, CU, BIS, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI