Характеристики серии

NAS Scaling:

1–24 nodes (12 HA pairs)

Maximum drives (HDD/SSD):

5,760/5,760

Maximum capacity:

57PB

Maximum onboard NVMe Flash Cache:

48TB

Maximum Flash Pool capacity:

576TB

Maximum memory:

3072GB

SAN Scaling:

1–12 nodes (6 HA pairs)

Maximum drives:

2,880/2,880

Maximum capacity:

28PB

Maximum onboard NVMe Flash Cache:

24TB

Maximum Flash Pool capacity:

288TB

Maximum memory:

1536GB

Cluster interconnect:

2 10GbE

Maximum drives (HDD/SSD):

480/480

Maximum capacity:

4.8PB

Controller form factor:

Single-enclosure HA;
2 controllers in single 3U chassis

Memory:

256GB

Maximum onboard NVMe Flash Cache:

4TB

Maximum Flash Pool capacity:

48TB

Combined flash total:

48TB

NVRAM:

16GB

PCIe expansion slots:

4

Onboard I/O: UTA2 (8Gb/16Gb FC, GbE/10GbE, or FCVI ports [MetroCluster only]):

8

Onboard I/O: 10GbE:

4

Onboard 10GbE Base-T:

4

Onboard I/O: 12Gb SAS:

8

Storage networking supported:

FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB

OS version:

ONTAP® 9.1
RC1 or higher

High-availability features:

Ethernet-based service processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies.

Supported Configurations ONTAP 9.1 or higher:

Hardware cluster configurations:

  • Two-node switchless or switched cluster
  • Clusters of HA pairs

MetroCluster configurations for synchronous replication:

  • 2-node
  • 4-node: two x 2-node switched or switchless clusters with fabric-attached (switched) storage; 4 nodes total: a 2-node active-active cluster at each site)
  • 8-node (NAS-only): four x 2-node switched or switchless clusters with fabric-attached (switched) storage; 8 nodes total: a 4-node cluster at each site)
Disk shelves supported:

DS224C (2U; 24 drives, 2.5” SFF, 12Gb)
DS212C (2U; 12 drives, 3.5” LFF, 12Gb)
DS460C (4U; 60 drives, 3.5” LFF, 12Gb)
DS2246 (2U; 24 drives, 2.5″ SFF, 6Gb)
DS4246 (4U; 24 drives, 3.5″ LFF, 6Gb)
DS4246 (DS4243 with IOM3 changed to IOM6)
DS4486 (4U; 48 drives, 3.5″ LFF, 6Gb)

Maximum RAID group sizes:

RAID-TEC™ (triple parity)

  • SSDs and Performance HDDs: 29 (26 data disks plus 3 parity disks)
  • Capacity HDDs: 29 (26 data disks plus 3 parity disks)

RAID 6 (RAID-DP®)

  • SSDs and Performance HDDs: 28 (26 data disks plus 2 parity disks)
  • Capacity HDDs: 20 (18 data disks plus 2 parity disks)

RAID 4

  • SSDs and Performance HDDs: 14 (13 data disks plus 1 parity disk)
  • Capacity HDDs: 7 (6 data disks plus 1 parity disk)

RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®)

Operating systems supported:

Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows Server 2016, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX®

Max. number of LUNs:

12,288

Number of supported SAN hosts:

8,192

FlexVol® volumes:

Up to 1,000 per controller

Snapshot® copies:

Up to 255,000 per controller

Maximum volume size:

100TB

Maximum aggregate size:

400TB

FC target ports (32Gb autoranging):

8

FC target ports (16Gb autoranging):

24

FC target ports (4Gb or 8Gb):

16

FCoE target ports, UTA (max.):

24

40GbE:

8

10GbE ports (max.):

24

10GbE Base-T ports (max.):

4

6Gb/12Gb SAS ports (max.):

24

FC initiator ports (max.):

24

32Gb FC:

4

40GbE:

4

Dual 10GbE (optical or copper):

4

Dual 10Gbase-T (RJ-45,CAT 6A-E):

4

Quad GbE (copper):

4

Dual 10GbE/FCoE 16Gb FC Unified Target Adapter 2 (UTA2, optical or copper for 10GbE/FCoE deployments, optical for 16Gb FC):

4

8Gb FC target:

4

Quad 12Gb SAS storage HBA:

4

Quad 4Gb FC storage/tape HBA (fiber):

4

Thermal Rating (at 200V):

1,850 BTU (typical)
2,130 BTU (worst case)

Power supply / cooling fans:

Dual, hot pluggable, integrated power supply/fan assemblies

AC input power voltage (autoranging, VRMS):

100-120V, 200-240V

AC input power frequency:

50-60 Hz

Weight:

78.92 lbs

Depth:

19″ (48 cm)

Operating temperature, altitude, and relative humidity:

41°F to 113°F (5°C to 45°C); at ≤ 3,000m (at ≤ 10,000′) elevation; 8% to 90% relative humidity, noncondensing

Nonoperating temperature and relative humidity:

-40°F to 158°F (-40°C to 70°C); at ≤ 12,192m (at ≤ 40,000′) typical of unconditioned airplane cargo bay, 10% to 95% relative humidity, noncondensing, in original container

Operating acoustic noise:

FAS8200:

  • Declared sound power (LwAd) per ISO 9296: 7.8 Bel
  • Sound pressure (LpAm) (bystander positions): 62.6 dB
Safety/Emissions/Immunity:

Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, CU, BIS, BSMI, SONCAP, NRCS LOA (South Africa)

Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI

Rack Space:

42U

Dimensions (height/weight/depth):

78.75″ (200cm)/23.6″ (60cm)/44.3″ (112.5cm)

Minimum Cabinet Clearances for Airflow:

10″ (25.4cm) front and 12″ (30.5cm) rear

Minimum Cabinet Clearances for Service:

30″ (76.3 cm) front and rear, 12″ top

AC Power:

200 to 240VAC

Current:

30A Single Phase or 3-Phase

Weight (empty):

307lb. (138kg)