StorageTek T10000D (24 drives, 252 MB/sec) – 21.8 TB/hr.
StorageTek LTO7 (24 drives, 300 MB/sec) – 25.9 TB/hr.
StorageTek LTO6 (24 drives, 160 MB/sec) – 13.8 TB/hr.
StorageTek T10000D (24 drives, 252 MB/sec) – 21.8 TB/hr.
StorageTek LTO7 (24 drives, 300 MB/sec) – 25.9 TB/hr.
StorageTek LTO6 (24 drives, 160 MB/sec) – 13.8 TB/hr.
StorageTek T10000D (320 carts, 8 TB/cart) – 2.5 PB
StorageTek LTO7 (320 carts, 6 TB/cart) – 1.9 PB
StorageTek LTO6 (320 carts, 2.5TB/cart) – 800 TB
200 to 5,925 customer-usable slots
1 to 56 drives in any combination of supported drives, including StorageTek T10000 Fibre Channel and FICON; StorageTek T9840, Fibre Channel, and FICON; and LTO Fibre Channe
One standard, 26-slot CAP (with optional CAP on drive and cartridge expansion modules), 234-slot bulk-load CAP per optional Access Expansion Module (AEM)
PDU (optional2N), CAP motor and control card, cooling fans, DC power supplies, tape drives, robotics (with AEM), and library electronics (optional redundant electronics)
2,000,000 per robot
0.99992 (with 2N power, redundant electronics, redundant robotics, and AEM)
Wide variety, including Oracle Solaris, Oracle Linux, z/OS, AS/400, AIX, HP-UX, and Windows environments; please check with your Oracle account rep for your specific environment.
TCP/IP (IEEE 802.3, 100BASE-T, half-duplex) with HSC or ACSLS, SMC-3 media changer command set with 8 Gb Fibre Channel.
Any supported cartridge type can be placed in any cell; no partitions or special drive or cartridge frames are required
TCP/IP remote monitoring is standard. Touch screen operator panel is optional.
Unique digital vision camera system performs continuous calibration and reads bar codes.
No periodic maintenance or alignment required.
Auto-discovery and auto-configuration for all drives, media types, slots, and CAP.
Additional dedicated cleaning cartridge slots are included for tape drive cleaning for multiple drive types by library or software command.
77.6 in. / 1.97 m
49.0 in. / 124 cm
36.0 in. / 91.5 cm
790 lb. / 361 kg (Base)
+60°F to +90°F (+16°C to +32°C)
+50°F to + 104°F (+10°C to + 40°C)
20% – 80%
20% – 80%
Choice of 100 VAC – 127 VAC or 200 VAC – 240 VAC @ 50 Hz – 60 Hz
Varies (refer to individual drive specifications)
Varies by configuration
Standard N+1 for DC power supplies; optional 2N for AC power source; optional 2N+1 for AC and DC redundancy
UL 60950-1; CAN/CSA-C22.2 No. 60950-1; EN/IEC 60950-1, -23
FCC (47 CFR 15, Subpart B) Class A; CE (EN55022 Class A, EN61000-3-2, EN61000-3-3); VCCI V-3 Class A; ICES-003 Class A, KN22 Class A, and AS/NZS CISPR22 Class A
EN55024, KN24, and CISPR24